STING Total Assay Kit Human
Opens in a new tab
Assay points.
-
ALSU-TSTNG-A500
500
-
ALSU-TSTNG-A10K
10,000
-
ALSU-TSTNG-A50K
50,000
-
ALSU-TSTNG-A-HV
100
Assay Principle
The AlphaLISA™ SureFire® Ultra™ assay enables the rapid and sensitive detection of total and phosphorylated cellular proteins. AlphaLISA™ assays utilize two bead types: Acceptor Beads and Donor Beads. The Acceptor Bead is coated with a proprietary CaptSure™ agent to specifically immobilize the assay specific antibody which is labeled with a CaptSure™ tag. The Donor Bead is coated with streptavidin to capture the biotinylated antibody.
In the presence of a target protein, the two target-specific antibodies bring Donor and Acceptor Beads into close proximity. When the Donor Beads are activated by a laser (680 nm), singlet oxygen is transferred to the Acceptor Bead leading to the production of an Alpha signal. The amount of light emission (615 nm) from the Acceptor Bead is directly proportional to the amount of target protein present in the sample. If an Acceptor Bead is not in close proximity (i.e. 200 nm) of a Donor bead, little to no signal is produced over background.
The assay can be executed in a 1-plate or 2-plate assay protocol (Refer to Manual for more details).
1-plate assay protocol: culturing of cells, treatment, lysis and assay are performed in a single well, enabling miniaturization in high throughput screening programs.
2-plate assay protocol: cells are cultured and treated in a 96-well culture plate and lysates are then transferred into a separate plate for assay. This format allows the evaluation of multiple targets from a single lysate.
Technical Specific Data
Data obtained with a 2-plate, 2-incubation protocol. Positive control lysate (THP-1) was serially diluted with Lysis Buffer B and assayed for Total and Phospho (Ser366) STING using respective SureFire® Ultra™ kit. Approximate number of cells/datapoint is indicated.
Data obtained from measurement of STING Total in various cell types lysed with Lysis Buffer. Approximate number of cells/datapoint is indicated for the various cell lines.
Data obtained with a 2-plate, 2-incubation protocol. THP-1 cells were seeded at 400K cells/well in complete medium and transfected with the indicated concentrations of Poly dA/dT for 4 hours. Cells were washed with HBSS and lysed with Lysis Buffer B. Lysates were assayed separately for Phospho (Ser366) and Total STING using respective SureFire® Ultra™ assay kits. Equivalent to approximately 40,000 cells/datapoint for Phospho (Ser366) and 4,000 cells/datapoint for STING Total.
Manuals & downloads.
-
PDF
-
PDF
Detection Kit Manual
-
Tech Spec
Technical Data Sheet
Safety Data Sheets
-
Safety Data Sheet (SDS)
Safety Data Sheet EU-EN
-
Safety Data Sheet (SDS)
Safety Data Sheet US